BA310 LED Trinocular Phase

Binocular microscope for advanced work in life sciences. Sections, smears and dispersions can be checked by CCIS© Plan Achromat objectives. Lab technicians benefit from the Full-Koehler illumination with a 3W LED light source, ready to work on unstained or weakly-stained structures from biology and medicine.
Product code
1200100401512
2,608.00€
Prices shown are the Manufacturer’s Suggested Retail Prices (MSRP) and may vary depending on the country. Prices do not include VAT, nor shipping, installation, insurance or any other additional services or taxes.
Prices shown are the Manufacturer’s Suggested Retail Prices (MSRP) and may vary depending on the country. Prices do not include VAT, nor shipping, installation, insurance or any other additional services or taxes.
Specifications
Model BA310 LED Trinocular Phase
Observation tube Trinocular head, Siedentopf type, 360º swiveling
Optical system Colour Corrected Infinity Optical System (CCIS®)
Inclination 30º inclined, 360º rotating
Trinocular light split 100:0/20:80 (optional 100:0/0:100)
Interpupillary distance 48-75mm
Diopter adjustment On both eyepieces, +/- 5 diopter
Eyepieces Widefield N-WF10X/20mm with diopter adjustment
Nosepiece Reversed quintuple
Objective classification CCIS® EC Plan Achromatic, EC-H Plan Phase, DIN
Objectives 4X/0.10 (WD 15.9mm), PH10X/0.25 (WD 17.4mm), PH40X/0.65 (WD 0.5mm), PH100X/1.25 (WD 0.15mm)
Objective mounting thread W 4/5"x1/36" (RMS standard)
Stand type Upright
Stage Mechanical stage with built-in low position coaxial stage control with tension adjustment and 2-sample holder
Stage size 175x140mm
Travel range X&Y 76x50mm
Condenser Phase contrast 5 position turret condenser N.A. 0.90 (BF, DF, Ph1, Ph2, Ph3)
Diaphragm Iris diaphragm
Focus mechanism Coaxial coarse and fine focusing system with tension adjustment
Fine focus precision 2µm
Focusing stroke 20mm
Upper limit stop Upper limit stop preset but adjustable
Filter holder On top of the illuminator
Transmitted illumination Koehler LED 3W with intensity control
Transformer Internal
Power supply 100-240V (CE)
Accessories included Dust cover, power cord, Allen key, Immersion oil (5ml), thumb screw, Phase centering telescope, centering keys
Dimensions LxWxH 400x220x400mm
Weight Net 8.6kg
Contrast techniques
Standard contrast technique Brightfield, phase contrast
Phase contrast Turret
Polarization Optional add-on
Darkfield Turret

Specification sheets

  • BA310 LED Trinocular PHASE - SpecSheet File size: 235.11 KB
    Language: English

Images

BA310 LED Trinocular PHASE - IMG
Download
BA310 LED Trinocular PHASE - DETAIL1 - IMG
Download
BA310 LED Trinocular PHASE - DETAIL2 - IMG
Download
BA310 LED Trinocular PHASE - DETAIL3 - IMG
Download

Guides

  • Basic microscopy concepts. Resolution and magnification - Guide File size: 410.11 KB
    Language: English
  • Basic microscopy concepts. Phase contrast adjustment - Guide File size: 462.97 KB
    Language: English
  • Basic microscopy concepts. Parfocality adjustment for upright microscopes - Guide File size: 330.83 KB
    Language: English
  • Basic microscopy concepts. Magnification on screen - Guide File size: 330.69 KB
    Language: English
  • Basic microscopy concepts. Koehler illumination - Guide File size: 441.58 KB
    Language: English
  • Basic microscopy concepts. Understanding the Field of view - Guide File size: 285.41 KB
    Language: English
  • Safety recommendations. How to ensure a clean microscope -Guide File size: --
  • How to mount Moticam 1080 INT BA Series - guide File size: --

Motic's BA310 & BA310E Overview | by Motic Europe

Meet the BA310 and the BA310E Series in depth. In this video, our product specialist Dr. Hans-Jürgen Klemenz, explains what are the differences between both models.

Koehler Illumination - Setup & Alignment | by Motic Europe

Know how to use the Koehler illumination properly in the BA310, BA310E, BA410 and BA410E Series. By our product specialist Dr. Hans-Jürgen Klemenz.

Contrast Methods - Darkfield with turret solution for BA310, BA310E & BA410E | by Motic Europe

Discover how to perform the darkfield contrast method with the turret solution, in our BA series of upright microscopes BA310, BA310E and BA410E models. By our product specialist Dr. Hans-Jürgen Klemenz.

Contrast Methods - Darkfield with slider solution for BA series | by Motic Europe

Discover how to perform the darkfield contrast method with the slider solution, in our BA series of upright microscopes BA210, BA310, BA410 and its Elite versions. By our product specialist Dr. Hans-Jürgen Klemenz.

How to mount the Moticam 1080 INT onto BA Series microscope | by Motic Europe

Discover how to mount the Moticam 1080 INT Full HD camera onto a Motic's BA Series microscope by following a few easy steps. Learn first how to mount the Moticam's 1080 INT screen onto the camera's body and then, how to mount the complete system into a BA microscope.

How to change the halogen bulb & LED module of a BA210, BA310, BA210E and BA310E | by Motic Europe

Learn how easy it is to replace the halogen bulb and the LED module and how to interchange the halogen/LED illumination in your Motic BA210, BA310, BA210E and BA310E microscopes. Valid for: BA210, BA310, BA210E and BA310E models.

How to replace the PCB LED illumination of a BA210 and a BA310 LED | by Motic Europe

Learn how easy it is to replace the PCB LED illumination of BA210 and a BA310 LED microscopes. Valid for: BA210 LED and BA310 LED models.

How to adjust the tension of the focusing system (ring). E.g. AE Series | by Motic Europe

Learn how easy it is to adjust the tension of the focusing system of your Motic microscope. Valid for: BA Series / AE Series / RED200 Series / SWIFT200 Series / B1 ELITE Series / B3 Series / 28 Series / BA50&80 Series / RED130, 131 and 132 models / SWIFT130X and 132 models.

Accessories for this model
Specifications
Model BA310 LED Trinocular Phase
Observation tube Trinocular head, Siedentopf type, 360º swiveling
Optical system Colour Corrected Infinity Optical System (CCIS®)
Inclination 30º inclined, 360º rotating
Trinocular light split 100:0/20:80 (optional 100:0/0:100)
Interpupillary distance 48-75mm
Diopter adjustment On both eyepieces, +/- 5 diopter
Eyepieces Widefield N-WF10X/20mm with diopter adjustment
Nosepiece Reversed quintuple
Objective classification CCIS® EC Plan Achromatic, EC-H Plan Phase, DIN
Objectives 4X/0.10 (WD 15.9mm), PH10X/0.25 (WD 17.4mm), PH40X/0.65 (WD 0.5mm), PH100X/1.25 (WD 0.15mm)
Objective mounting thread W 4/5"x1/36" (RMS standard)
Stand type Upright
Stage Mechanical stage with built-in low position coaxial stage control with tension adjustment and 2-sample holder
Stage size 175x140mm
Travel range X&Y 76x50mm
Condenser Phase contrast 5 position turret condenser N.A. 0.90 (BF, DF, Ph1, Ph2, Ph3)
Diaphragm Iris diaphragm
Focus mechanism Coaxial coarse and fine focusing system with tension adjustment
Fine focus precision 2µm
Focusing stroke 20mm
Upper limit stop Upper limit stop preset but adjustable
Filter holder On top of the illuminator
Transmitted illumination Koehler LED 3W with intensity control
Transformer Internal
Power supply 100-240V (CE)
Accessories included Dust cover, power cord, Allen key, Immersion oil (5ml), thumb screw, Phase centering telescope, centering keys
Dimensions LxWxH 400x220x400mm
Weight Net 8.6kg
Contrast techniques
Standard contrast technique Brightfield, phase contrast
Phase contrast Turret
Polarization Optional add-on
Darkfield Turret

Specification sheets

  • BA310 LED Trinocular PHASE - SpecSheet File size: 235.11 KB
    Language: English

Images

BA310 LED Trinocular PHASE - IMG
Download
BA310 LED Trinocular PHASE - DETAIL1 - IMG
Download
BA310 LED Trinocular PHASE - DETAIL2 - IMG
Download
BA310 LED Trinocular PHASE - DETAIL3 - IMG
Download

Guides

  • Basic microscopy concepts. Resolution and magnification - Guide File size: 410.11 KB
    Language: English
  • Basic microscopy concepts. Phase contrast adjustment - Guide File size: 462.97 KB
    Language: English
  • Basic microscopy concepts. Parfocality adjustment for upright microscopes - Guide File size: 330.83 KB
    Language: English
  • Basic microscopy concepts. Magnification on screen - Guide File size: 330.69 KB
    Language: English
  • Basic microscopy concepts. Koehler illumination - Guide File size: 441.58 KB
    Language: English
  • Basic microscopy concepts. Understanding the Field of view - Guide File size: 285.41 KB
    Language: English
  • Safety recommendations. How to ensure a clean microscope -Guide File size: --
  • How to mount Moticam 1080 INT BA Series - guide File size: --

Motic's BA310 & BA310E Overview | by Motic Europe

Meet the BA310 and the BA310E Series in depth. In this video, our product specialist Dr. Hans-Jürgen Klemenz, explains what are the differences between both models.

Koehler Illumination - Setup & Alignment | by Motic Europe

Know how to use the Koehler illumination properly in the BA310, BA310E, BA410 and BA410E Series. By our product specialist Dr. Hans-Jürgen Klemenz.

Contrast Methods - Darkfield with turret solution for BA310, BA310E & BA410E | by Motic Europe

Discover how to perform the darkfield contrast method with the turret solution, in our BA series of upright microscopes BA310, BA310E and BA410E models. By our product specialist Dr. Hans-Jürgen Klemenz.

Contrast Methods - Darkfield with slider solution for BA series | by Motic Europe

Discover how to perform the darkfield contrast method with the slider solution, in our BA series of upright microscopes BA210, BA310, BA410 and its Elite versions. By our product specialist Dr. Hans-Jürgen Klemenz.

How to mount the Moticam 1080 INT onto BA Series microscope | by Motic Europe

Discover how to mount the Moticam 1080 INT Full HD camera onto a Motic's BA Series microscope by following a few easy steps. Learn first how to mount the Moticam's 1080 INT screen onto the camera's body and then, how to mount the complete system into a BA microscope.

How to change the halogen bulb & LED module of a BA210, BA310, BA210E and BA310E | by Motic Europe

Learn how easy it is to replace the halogen bulb and the LED module and how to interchange the halogen/LED illumination in your Motic BA210, BA310, BA210E and BA310E microscopes. Valid for: BA210, BA310, BA210E and BA310E models.

How to replace the PCB LED illumination of a BA210 and a BA310 LED | by Motic Europe

Learn how easy it is to replace the PCB LED illumination of BA210 and a BA310 LED microscopes. Valid for: BA210 LED and BA310 LED models.

How to adjust the tension of the focusing system (ring). E.g. AE Series | by Motic Europe

Learn how easy it is to adjust the tension of the focusing system of your Motic microscope. Valid for: BA Series / AE Series / RED200 Series / SWIFT200 Series / B1 ELITE Series / B3 Series / 28 Series / BA50&80 Series / RED130, 131 and 132 models / SWIFT130X and 132 models.

Accessories for this model