SMZ-171-BLED
Model | SMZ-171-BLED |
---|---|
Observation tube | Binocular head |
Optical system | Greenough |
Inclination | 45º inclined |
Interpupillary distance | 52-75mm |
Diopter adjustment | On both eyepieces, +/- 5 diopter |
Eyepieces | Widefield N-WF10X/23mm with diopter adjustment |
Objectives system | Zoom, ratio 6.7:1 |
Objectives | 0.75X~5X |
Working distance | 110mm |
Stand type | Pole type stand with transmitted illumination |
Head holder | For Ø32mm column and Ø76mm head |
Focus mechanism | Coarse focusing system with tension adjustment |
Focusing stroke | 49mm |
Incident illumination | LED 3W with intensity control |
Transmitted illumination | LED 3W with reflector and intensity control |
Illumination features | Transmitted light with tilting reflector for oblique illumination |
Transformer | External |
Power supply | 100-240V (CE) |
Accessories included | Dust cover, black/white and frosted stage plates |
Dimensions LxWxH | 303x239x405mm |
Base | 303x239mm |
Column/Arm | Height 232mm, Ø32mm |
Weight Net | 5.95kg |
Contrast techniques | |
Standard contrast technique | Brightfield |
Polarization | Optional add-on |
Darkfield | Optional add-on |
Catalogues
-
SMZ171 - Diptych File size: --
-
SMZ171 - Catalogue File size: --
-
Life Sciences - Catalogue File size: 3.76 MBLanguage: German
-
Industry - Catalogue File size: 3.69 MBLanguage: German
Specification sheets
Images
Instructions
Guides
-
Basic concepts about stereo Microscopes - Guide File size: 457.25 KBLanguage: English
-
Basic microscopy concepts. Parfocality adjustment for upright microscopes - Guide File size: 330.83 KBLanguage: English
-
Basic microscopy concepts. Magnification on screen - Guide File size: 330.69 KBLanguage: English
-
Basic microscopy concepts. Understanding the Field of view - Guide File size: 285.41 KBLanguage: English
-
Safety recommendations. How to ensure a clean microscope -Guide File size: --
How to adjust the tension of the focusing system (hook key). E.g. SMZ168 | by Motic Europe
Learn how easy it is to adjust the tension of the focusing system of your Motic microscope. For models with Allen and hook key. Valid for: SMZ171 Series / SMZ168 Series / GM Series / RED30 Series / K Series / ST30 Series / S10&20 Series / SFC3 Series / SFC100 Series
How to replace the incident illumination of the SMZ171 and SMZ168 LED models | by Motic Europe
Discover how to replace the LED assembly of the incident illumination of your Motic SMZ171-BLED/TLED or SMZ168-BLED/T-LED stereo microscopes. Learn how to do it in a few easy steps. Valid for: SMZ171-BLED, SMZ171-TLED, SMZ168-BLED, SMZ168-TLED.
How to replace the transmitted illumination of the SMZ171 and SMZ168 LED models | by Motic Europe
Discover how to replace the LED assembly of the transmitted illumination of your Motic SMZ171-BLED/TLED or SMZ168-BLED/T-LED stereo microscopes. Learn how to do it in a few easy steps. Valid for: SMZ171-BLED, SMZ171-TLED, SMZ168-BLED, SMZ168-TLED.
Model | SMZ-171-BLED |
---|---|
Observation tube | Binocular head |
Optical system | Greenough |
Inclination | 45º inclined |
Interpupillary distance | 52-75mm |
Diopter adjustment | On both eyepieces, +/- 5 diopter |
Eyepieces | Widefield N-WF10X/23mm with diopter adjustment |
Objectives system | Zoom, ratio 6.7:1 |
Objectives | 0.75X~5X |
Working distance | 110mm |
Stand type | Pole type stand with transmitted illumination |
Head holder | For Ø32mm column and Ø76mm head |
Focus mechanism | Coarse focusing system with tension adjustment |
Focusing stroke | 49mm |
Incident illumination | LED 3W with intensity control |
Transmitted illumination | LED 3W with reflector and intensity control |
Illumination features | Transmitted light with tilting reflector for oblique illumination |
Transformer | External |
Power supply | 100-240V (CE) |
Accessories included | Dust cover, black/white and frosted stage plates |
Dimensions LxWxH | 303x239x405mm |
Base | 303x239mm |
Column/Arm | Height 232mm, Ø32mm |
Weight Net | 5.95kg |
Contrast techniques | |
Standard contrast technique | Brightfield |
Polarization | Optional add-on |
Darkfield | Optional add-on |
Catalogues
-
SMZ171 - Diptych File size: --
-
SMZ171 - Catalogue File size: --
-
Life Sciences - Catalogue File size: 3.76 MBLanguage: German
-
Industry - Catalogue File size: 3.69 MBLanguage: German
Specification sheets
Images
Instructions
Guides
-
Basic concepts about stereo Microscopes - Guide File size: 457.25 KBLanguage: English
-
Basic microscopy concepts. Parfocality adjustment for upright microscopes - Guide File size: 330.83 KBLanguage: English
-
Basic microscopy concepts. Magnification on screen - Guide File size: 330.69 KBLanguage: English
-
Basic microscopy concepts. Understanding the Field of view - Guide File size: 285.41 KBLanguage: English
-
Safety recommendations. How to ensure a clean microscope -Guide File size: --
How to adjust the tension of the focusing system (hook key). E.g. SMZ168 | by Motic Europe
Learn how easy it is to adjust the tension of the focusing system of your Motic microscope. For models with Allen and hook key. Valid for: SMZ171 Series / SMZ168 Series / GM Series / RED30 Series / K Series / ST30 Series / S10&20 Series / SFC3 Series / SFC100 Series
How to replace the incident illumination of the SMZ171 and SMZ168 LED models | by Motic Europe
Discover how to replace the LED assembly of the incident illumination of your Motic SMZ171-BLED/TLED or SMZ168-BLED/T-LED stereo microscopes. Learn how to do it in a few easy steps. Valid for: SMZ171-BLED, SMZ171-TLED, SMZ168-BLED, SMZ168-TLED.
How to replace the transmitted illumination of the SMZ171 and SMZ168 LED models | by Motic Europe
Discover how to replace the LED assembly of the transmitted illumination of your Motic SMZ171-BLED/TLED or SMZ168-BLED/T-LED stereo microscopes. Learn how to do it in a few easy steps. Valid for: SMZ171-BLED, SMZ171-TLED, SMZ168-BLED, SMZ168-TLED.