We use our own and third-party cookies to improve our services and show you advertising related to your preferences by analysing your browsing habits.
If you continue browsing, we consider this to mean that you accept their use You may change your settings or obtain more information in our - Cookies Policy - Hide this message

AE2000 Trinocular (without 40X)

Trinocular Inverted live cell microscope for routine microbiology. The pre-defined optical setup with LWD CCIS© Phase objectives (without 40X objective) is ready for the inspection of diverse native samples in cell culture flasks. Lab technicians profit from the convincing Phase contrast concept, while the Fixed-Koehler illumination with interchangeable light source (HAL/LED)... View More
Product code
1100103800139
Availability: Out of stock
2,524.00€
Prices shown are the Manufacturer’s Suggested Retail Prices (MSRP) and may vary depending on the country. Prices do not include VAT, nor shipping, installation, insurance or any other additional services or taxes.
Prices shown are the Manufacturer’s Suggested Retail Prices (MSRP) and may vary depending on the country. Prices do not include VAT, nor shipping, installation, insurance or any other additional services or taxes.
Specifications
Model AE2000 Trinocular (without 40X)
Observation tube Trinocular head, Siedentopf type, 360º swiveling
Optical system Colour Corrected Infinity Optical System (CCIS®)
Inclination 45º inclined
Trinocular light split 100:0/20:80
Interpupillary distance 48-75mm
Diopter adjustment On both eyepieces, +/- 5 diopter
Eyepieces Widefield N-WF10X/20mm with diopter adjustment
Nosepiece Left side facing quadruple
Objective classification CCIS® Plan Achromatic, DIN
Objectives 4X/0.10 (WD 12.6mm), PH10X/0.25 (WD 4.1mm), LWD PH20X/0.30 (WD 4.7mm)
Objective mounting thread W 4/5"x1/36" (RMS standard)
Stand type Inverted
Stage Plain stage with metal and glass stage inserts
Stage size 200x239mm
Condenser ELWD condenser N.A. 0.30 (WD = 72mm) with filter holder
Diaphragm Iris diaphragm
Focus mechanism Coaxial coarse and fine focusing system with tension adjustment
Fine focus precision 2µm
Focusing stroke 8mm
Free working distance Working distance without condenser 184mm
Transmitted illumination Quartz Halogen 6V/30W with intensity control
Illumination interchangeability Quartz halogen 6V/30W or LED 3W
Illumination features Auto on/off
Transformer External
Power supply 100-240V (CE)
Accessories included Dust cover, power cord, blue, green and neutral density filters, phase ring Ph1, centering telescope, centering keys
Dimensions LxWxH 556x218x496mm
Weight Net 12.2kg
Contrast techniques
Standard contrast technique Brightfield, phase contrast
Phase contrast Slider

Catalogues

  • Life Sciences - Catalogue File size: --
  • AE2000 - Catalogue File size: 3.46 MB
    Language: English
  • AE2000 - Diptych File size: 1.33 MB
    Language: English

Specification sheets

  • AE2000 Trinocular w/40x - SpecSheet File size: 183.21 KB
    Language: English

Images

AE2000 Trinocular (without 40X)
Download
AE2000 Trinocular (without 40X) - DETAIL1
Download
AE2000 Trinocular (without 40X) - DETAIL2
Download
AE2000 Trinocular (without 40X) - DETAIL3
Download
AE2000 Trinocular (without 40X) - DETAIL4
Download
AE2000 Trinocular (without 40X) - DETAIL5
Download
AE2000 Series
Download

Instructions

  • AE2000 Series - User Manual File size: --

Guides

  • Quick inverted microscope setup - Guide File size: 823.75 KB
    Language: English
  • Basic microscopy concepts. Resolution and magnification - Guide File size: 410.11 KB
    Language: English
  • Basic microscopy concepts. Phase contrast adjustment - Guide File size: 462.97 KB
    Language: English
  • Basic microscopy concepts. Parfocality adjustment for upright microscopes - Guide File size: 353.65 KB
    Language: English
  • Basic microscopy concepts. Magnification on screen - Guide File size: 330.69 KB
    Language: English
  • Basic microscopy concepts. Understanding the Field of view - Guide File size: 285.41 KB
    Language: English

Contrast Methods - Phase Contrast on AE2000 & AE31E | by Motic Europe

Discover how to perform the Phase contrast method on our AE2000 & AE31E inverted microscopes. By our product specialist Dr. Hans-Jürgen Klemenz. http://www.moticeurope.com/product/life-sciences/inverted-microscopes/ae2000-series/ http://www.moticeurope.com/product/life-sciences/inverted-microscopes/ae31-elite-series/

How to adjust the tension of the focusing system (ring). E.g. AE Series | by Motic Europe

Learn how easy it is to adjust the tension of the focusing system of your Motic microscope. Valid for: BA Series / AE Series / RED200 Series / SWIFT200 Series / B1 ELITE Series / B3 Series / 28 Series / BA50&80 Series / RED130, 131 and 132 models / SWIFT130X and 132 models. #MoticHowTo #MoticEurope #Motic

Accessories for this model
Specifications
Model AE2000 Trinocular (without 40X)
Observation tube Trinocular head, Siedentopf type, 360º swiveling
Optical system Colour Corrected Infinity Optical System (CCIS®)
Inclination 45º inclined
Trinocular light split 100:0/20:80
Interpupillary distance 48-75mm
Diopter adjustment On both eyepieces, +/- 5 diopter
Eyepieces Widefield N-WF10X/20mm with diopter adjustment
Nosepiece Left side facing quadruple
Objective classification CCIS® Plan Achromatic, DIN
Objectives 4X/0.10 (WD 12.6mm), PH10X/0.25 (WD 4.1mm), LWD PH20X/0.30 (WD 4.7mm)
Objective mounting thread W 4/5"x1/36" (RMS standard)
Stand type Inverted
Stage Plain stage with metal and glass stage inserts
Stage size 200x239mm
Condenser ELWD condenser N.A. 0.30 (WD = 72mm) with filter holder
Diaphragm Iris diaphragm
Focus mechanism Coaxial coarse and fine focusing system with tension adjustment
Fine focus precision 2µm
Focusing stroke 8mm
Free working distance Working distance without condenser 184mm
Transmitted illumination Quartz Halogen 6V/30W with intensity control
Illumination interchangeability Quartz halogen 6V/30W or LED 3W
Illumination features Auto on/off
Transformer External
Power supply 100-240V (CE)
Accessories included Dust cover, power cord, blue, green and neutral density filters, phase ring Ph1, centering telescope, centering keys
Dimensions LxWxH 556x218x496mm
Weight Net 12.2kg
Contrast techniques
Standard contrast technique Brightfield, phase contrast
Phase contrast Slider

Catalogues

  • Life Sciences - Catalogue File size: --
  • AE2000 - Catalogue File size: 3.46 MB
    Language: English
  • AE2000 - Diptych File size: 1.33 MB
    Language: English

Specification sheets

  • AE2000 Trinocular w/40x - SpecSheet File size: 183.21 KB
    Language: English

Images

AE2000 Trinocular (without 40X)
Download
AE2000 Trinocular (without 40X) - DETAIL1
Download
AE2000 Trinocular (without 40X) - DETAIL2
Download
AE2000 Trinocular (without 40X) - DETAIL3
Download
AE2000 Trinocular (without 40X) - DETAIL4
Download
AE2000 Trinocular (without 40X) - DETAIL5
Download
AE2000 Series
Download

Instructions

  • AE2000 Series - User Manual File size: --

Guides

  • Quick inverted microscope setup - Guide File size: 823.75 KB
    Language: English
  • Basic microscopy concepts. Resolution and magnification - Guide File size: 410.11 KB
    Language: English
  • Basic microscopy concepts. Phase contrast adjustment - Guide File size: 462.97 KB
    Language: English
  • Basic microscopy concepts. Parfocality adjustment for upright microscopes - Guide File size: 353.65 KB
    Language: English
  • Basic microscopy concepts. Magnification on screen - Guide File size: 330.69 KB
    Language: English
  • Basic microscopy concepts. Understanding the Field of view - Guide File size: 285.41 KB
    Language: English

Contrast Methods - Phase Contrast on AE2000 & AE31E | by Motic Europe

Discover how to perform the Phase contrast method on our AE2000 & AE31E inverted microscopes. By our product specialist Dr. Hans-Jürgen Klemenz. http://www.moticeurope.com/product/life-sciences/inverted-microscopes/ae2000-series/ http://www.moticeurope.com/product/life-sciences/inverted-microscopes/ae31-elite-series/

How to adjust the tension of the focusing system (ring). E.g. AE Series | by Motic Europe

Learn how easy it is to adjust the tension of the focusing system of your Motic microscope. Valid for: BA Series / AE Series / RED200 Series / SWIFT200 Series / B1 ELITE Series / B3 Series / 28 Series / BA50&80 Series / RED130, 131 and 132 models / SWIFT130X and 132 models. #MoticHowTo #MoticEurope #Motic

Accessories for this model