AE2000MET Series >
Know more about this Series
AE2000 MET Trinocular 100W (with LM PL objectives)
Inverted metallurgical microscope for the inspection of bulky samples in automotive-, machinery- and steel industry. Large metal pieces and die casting parts, too large for an upright microscope are easily examined to perform failure analysis, material research and quality control. Incident Brightfield illumination is an integral part of the instrument’s performance.
Inverted metallurgical microscope for the inspection of bulky samples in automotive-, machinery- and steel industry. Large metal pieces and die casting parts, too large for an upright microscope are easily examined to perform failure analysis, material research and quality control. Incident Brightfield illumination is an integral part of the instrument’s performance. View Less
Product code
1100103800158
5,021.00€
Prices shown are the Manufacturer’s Suggested Retail Prices (MSRP) and may vary depending on the country. Prices do not include VAT, nor shipping, installation, insurance or any other additional services or taxes.
Add to Wish List
Add to Compare
Prices shown are the Manufacturer’s Suggested Retail Prices (MSRP) and may vary depending on the country. Prices do not include VAT, nor shipping, installation, insurance or any other additional services or taxes.
Model | AE2000 MET Trinocular 100W (with LM PL objectives) |
---|---|
Observation tube | Trinocular head, Siedentopf type, 360º swiveling |
Optical system | Colour Corrected Infinity Optical System (CCIS®) |
Inclination | 45º inclined |
Trinocular light split | 100:0/20:80 |
Interpupillary distance | 48-75mm |
Diopter adjustment | On both eyepieces, +/- 5 diopter |
Eyepieces | Widefield N-WF10X/20mm with diopter adjustment |
Nosepiece | Side facing quintuple |
Objective classification | CCIS® LM Plan Achromatic, DIN |
Objectives | 5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm) |
Objective mounting thread | M32 with adapters to W 4/5" x 1/36" (RMS standard) |
Stand type | Inverted |
Stage | Mechanical stage, hard coated with built-in low position coaxial stage control with round and oval stage inserts |
Stage size | 280x192mm |
Travel range X&Y | 50x50mm |
Focus mechanism | Coaxial coarse and fine focusing system with tension adjustment |
Fine focus precision | 2µm |
Focusing stroke | 10mm |
Transmitted illumination | Koehler Quartz halogen 12V/100W with intensity control, External lamphouse |
Illumination features | Sleeping mode |
Transformer | External |
Power supply | 100-240V (CE) |
Accessories included | Dust cover, power cord, Allen key, blue filter |
Dimensions LxWxH | 673x280x345mm |
Weight Net | 13kg |
Contrast techniques | |
Standard contrast technique | Brightfield |
Polarization | Optional sliders |
Catalogues
Specification sheets
Images
Instructions
Guides
-
Quick inverted microscope setup - Guide File size: 823.75 KBLanguage: English
-
Basic microscopy concepts. Resolution and magnification - Guide File size: 410.11 KBLanguage: English
-
Basic microscopy concepts. Parfocality adjustment for upright microscopes - Guide File size: 353.65 KBLanguage: English
-
Basic microscopy concepts. Magnification on screen - Guide File size: 330.69 KBLanguage: English
-
Basic microscopy concepts. Understanding the Field of view - Guide File size: 285.41 KBLanguage: English
-
Safety recommendations. How to ensure a clean microscope -Guide File size: --
How to adjust the tension of the focusing system (ring). E.g. AE Series | by Motic Europe
Learn how easy it is to adjust the tension of the focusing system of your Motic microscope. Valid for: BA Series / AE Series / RED200 Series / SWIFT200 Series / B1 ELITE Series / B3 Series / 28 Series / BA50&80 Series / RED130, 131 and 132 models / SWIFT130X and 132 models.
Related Models
Accessories for this model
Model | AE2000 MET Trinocular 100W (with LM PL objectives) |
---|---|
Observation tube | Trinocular head, Siedentopf type, 360º swiveling |
Optical system | Colour Corrected Infinity Optical System (CCIS®) |
Inclination | 45º inclined |
Trinocular light split | 100:0/20:80 |
Interpupillary distance | 48-75mm |
Diopter adjustment | On both eyepieces, +/- 5 diopter |
Eyepieces | Widefield N-WF10X/20mm with diopter adjustment |
Nosepiece | Side facing quintuple |
Objective classification | CCIS® LM Plan Achromatic, DIN |
Objectives | 5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm) |
Objective mounting thread | M32 with adapters to W 4/5" x 1/36" (RMS standard) |
Stand type | Inverted |
Stage | Mechanical stage, hard coated with built-in low position coaxial stage control with round and oval stage inserts |
Stage size | 280x192mm |
Travel range X&Y | 50x50mm |
Focus mechanism | Coaxial coarse and fine focusing system with tension adjustment |
Fine focus precision | 2µm |
Focusing stroke | 10mm |
Transmitted illumination | Koehler Quartz halogen 12V/100W with intensity control, External lamphouse |
Illumination features | Sleeping mode |
Transformer | External |
Power supply | 100-240V (CE) |
Accessories included | Dust cover, power cord, Allen key, blue filter |
Dimensions LxWxH | 673x280x345mm |
Weight Net | 13kg |
Contrast techniques | |
Standard contrast technique | Brightfield |
Polarization | Optional sliders |
Catalogues
Specification sheets
Images
Instructions
Guides
-
Quick inverted microscope setup - Guide File size: 823.75 KBLanguage: English
-
Basic microscopy concepts. Resolution and magnification - Guide File size: 410.11 KBLanguage: English
-
Basic microscopy concepts. Parfocality adjustment for upright microscopes - Guide File size: 353.65 KBLanguage: English
-
Basic microscopy concepts. Magnification on screen - Guide File size: 330.69 KBLanguage: English
-
Basic microscopy concepts. Understanding the Field of view - Guide File size: 285.41 KBLanguage: English
-
Safety recommendations. How to ensure a clean microscope -Guide File size: --
How to adjust the tension of the focusing system (ring). E.g. AE Series | by Motic Europe
Learn how easy it is to adjust the tension of the focusing system of your Motic microscope. Valid for: BA Series / AE Series / RED200 Series / SWIFT200 Series / B1 ELITE Series / B3 Series / 28 Series / BA50&80 Series / RED130, 131 and 132 models / SWIFT130X and 132 models.
Related Models
Accessories for this model